#1 - Accuracy of ARFI elastography in the differentiation of cataract stages in dogs

Abstract in English:

Objective was to evaluate the accuracy of elastography in the differentiation between normal and cataract lenses One hundred forty-five eyes of 98 dogs were divided into groups according to cataract stage. Forty-twoeyes were submitted to phacoemulsification. Biometric parameters, echogenicity and echotexture patterns of the anterior, posterior and vitreous chambers, lens and retina-choroid-sclera complexes were evaluated by ocular ultrasound in modes A and B. Deformability, and color (blue color = indicated less rigid structures, color red = more rigid structures) of the lenses were evaluated by the elastogram. The shear wave velocity (SWV; m/s) was calculated in three regions of the lens, both in the cortex and in the nucleus. The SWV of nucleus was statistically different between the normal lenses and with cataracts, and between the stages of cataract (P<0.001). Healthy lenses and incipient cataracts had a more rigid nucleus. Mature cataracts presented lowest nuclear rigidity (P<0.001). On cortical region the SWV was significantly higher (P<0.01) in intumescent and incipient cataracts. SWV less than 2.67m/s indicates cataract with a sensitivity of 72% and specificity of 94%. Values lower than 2.23m/s suggest mature cataract, with sensitivity of 71% and specificity of 76%. SWV greater than 2.66 m/s are associated with normal lenses or incipient cataract, presenting sensitivity of 94% and specificity of 84%. Qualitative method allowed differentiation between healthy and affected lenses and the classification of evolutionary stages. There was a correlation between the degree of stiffness of lens in cortical and nuclear regions (p=00165, r=0.37) and between the balanced saline solution quantitative and surgical time (P<0.01, r=0.73). Degree of stiffness of lens did not correlate with parameters of phacoemulsification. Elastographic proved feasible for evaluating the lens of dogs, characterizing the types of cataracts, and demonstrating increased stiffness of the diseased lenses.

Abstract in Portuguese:

O objetivo foi avaliar a precisão da elastografia na diferenciação entre lentes normais e de catarata. Cento e quarenta e cinco olhos de 98 cães foram divididos em grupos de acordo com o estágio de maturação da catarata. Quarenta e dois olhos foram submetidos à facoemulsificação. Parâmetros biométricos, ecogenicidade e padrões de ecotextura das câmaras anterior, posterior e vítrea, lente e complexos retina-coróide-esclera foram avaliados por ultrassonografia ocular nos modos A e B. A deformabilidade e a coloração (cor azul = indicou estruturas menos rígidas, cor vermelha = estruturas mais rígidas) das lentes foram avaliadas pelo elastograma. A velocidade da onda de cisalhamento (SWV; m/s) foi calculada em três regiões da lente, tanto no córtex quanto no núcleo. A SWV do núcleo foi estatisticamente diferente entre as lentes normais e com catarata e entre os estágios da catarata (P<0,001). Lentes saudáveis e cataratas incipientes tinham um núcleo mais rígido. Cataratas maduras apresentaram menor rigidez nuclear (P<0,001). Na região cortical, a SWV foi significativamente maior (P<0,01) nas cataratas intumescentes e incipientes. Uma SWV menor que 2,67m/s indica catarata com sensibilidade de 72% e especificidade de 94%. Valores inferiores a 2,23m/s sugerem catarata madura, com sensibilidade de 71% e especificidade de 76%. Uma SWV superior a 2,66m/s está associada à catarata normal ou incipiente, apresentando sensibilidade de 94% e especificidade de 84%. O método qualitativo permitiu a diferenciação entre lentes normais de olhos saudáveis e afetadas e a classificação dos estágios evolutivos. A elastografia se mostrara uma ferramenta viável para avaliar as lentes de cães, caracterizando os tipos de catarata e demonstrando maior rigidez das lentes doentes.


#2 - Intraocular pressure and tear secretion in Saanen goats with different ages, 30(9):798-802

Abstract in English:

ABSTRACT.- Ribeiro A.P., Piso D.Y.T., Padua I.R.M., Silva M.L. & Laus J.L. 2010. Intraocular pressure and tear secretion in Saanen goats with different ages. Pesquisa Veterinária Brasileira 30(9):798-802. Departamento de Clínica e Cirurgia Veterinária, Universidade Estadual Paulista, Via de acesso Professor Paulo Donato Castellane s/n, Jaboticabal, SP 14870-000, Brazil. E-mail: jllaus@fcav.unesp.br This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.

Abstract in Portuguese:

RESUMO.- Ribeiro A.P., Piso D.Y.T., Padua I.R.M., Silva M.L. & Laus J.L. 2010. Intraocular pressure and tear secretion in Saanen goats with different ages. [Pressão intraocular e produção lacrimal em cabras da raça Saanen com diferentes idades.] Pesquisa Veterinária Brasileira 30(9):798-802. Departamento de Clínica e Cirurgia Veterinária, Universidade Estadual Paulista, Via de acesso Professor Paulo Donato Castellane s/n, Jaboticabal, SP 14870-000, Brazil. E-mail: jllaus@fcav.unesp.br Objetivou-se comparar os valores normais de pressão intraocular (PIO) e de produção lacrimal, através de tonometria de aplanação e do teste da lágrima de Schirmer-1 (TLS-1) em cabras da raça Saanen, com diferentes idades e momentos. Trinta e seis cabras da raça Saanen, livres de afecções oculares, foram agrupadas em três categorias etárias (n=12), compreendendo animais com 45, 180 e 549 dias de idade. O TLS-1 e a PIO foram aferidos sempre às 9:00 e às 19:00, durante três dias consecutivos. Os resultados foram avaliados estatisticamente (p<0,05). Relativamente ao horário do dia, a PIO foi significativamente menor às 19:00 (p<0,001) nos animais com 45 dias de idade; os valores do TLS-1 foram significativamente maiores às 19:00 (p=0,004) nas cabras com 549 dias de idade. Considerando-se a somatória dos três dias, ambos os parâmetros foram significativamente menores nos indivíduos com 45 dias de idade (p<0,001). A pressão intraocular e a produção lacrimal em cabras da raça Saanen se elevam de forma significativa até os 180 dias de idade.